Measuring Moisture In Concrete
The water creates a chemical reaction in the cement causing it.
Measuring moisture in concrete. How concrete hardens and dries. This makes the rh test much faster than any other industry accepted method of measuring moisture in concrete slabs. That if moisture is detected the concrete is probably not ready for coating. In this test an 18 inch x 18 inch 450 measuring and removing moisture in concrete by don j.
Often more than one method is used to get an accurate reading of actual moisture content. By determining the moisture conditions both within and around the slab it is easier to determine exactly when it will be safe to develop on the concrete. Concrete is manufactured by mixing cement aggregates such as sand and gravel and water. A second direct test astm f 1869 standard test method for measuring moisture vapor emission rate of concrete subfloor using anhydrous calcium chloride was standardized in the 1990s by the subcommittee on practices of the committee on resilient floor coverings.
Now testers need only wait 24 hours. This requires accurate concrete moisture measurement. The biggest problem in connection with the concrete production is the variation in aggregate moisture and therefore it is an important task to make sure that measuring of the aggregate moisture is easy and as accurate as possible. Schnell munters corporation moisture control services 52 march 1998 jpcl pmc w before you coat concrete you need to know how much moisture it contains and how to.
Given the realities of moisture in concrete and the necessity of measuring the moisture condition of the concrete slab accurately only one clear conclusion exists. Concrete slabs appear to be solid and hard but in reality concrete is moist stuff. Under this method you ll use a thermo hygrometer with in situ probes along with a series of prepared holes to get readings of relative humidity deep in the concrete slab. Also known but less common in use are the hood method plastic sheet method and concrete moisture meters.
Inaccurate measuring of aggregate moisture increases production costs. It begins as a liquid slurry of water sand cement and aggregate and even after it hardens moisture continues to pass out of the concrete for years. What are the options. Before the change the standard required waiting 72 hours for rh sensors to acclimate in the concrete slab before taking moisture readings.
There are two main standards in the industry right now calcium chloride cacl testing and rh testing. Astm f2170 in situ rh testing will give you the most reliable information to help you manage your flooring project successfully. When measuring moisture in concrete the best and most reliable method is to use the astm f 2170 testing method.