Medical Gas Storage Room Requirements
Unfortunately inaccurate valve labeling is a very common problem in health care facilities.
Medical gas storage room requirements. Up to 20 000 cu. Carbon dioxide medical air nitrogen nitrous oxide helium argon and xenon. Nfpa 99 health care facilities code provides guidance to keep patients staff and the public safe in facilities with these types of cylinders. Nfpa 99 does not prohibit various medical gas cylinders from being stored in the same room as long as flammable and non flammable gasses are not comingled.
Guidelines for medical gas storage a newly updated nfpa white paper medical gas cylinder storage identifies the requirements of the 2018 edition of. Ft including providing 1 hour fire rated room construction ventilation and explosion proof electrical fixtures such as motors and lights. With the exception of medical air compressors no motor driven equipment is allowed in the same room with medical gas storage. There are no specific requirements for ventilation of the room.
This includes labeling of piping alarms and valves. While requirements were occasionally written into state administrative codes designers often relied on aia guideline recommendations when there was no clear direction. Unlike the no motor driven equipment requirement in the medical gas storage room labeling requirements are retroactive. Medical gas cylinder storage.
Storage temperatures must not exceed 130 degrees fahrenheit. Minimum requirements for medical gas services and outlets have for a long time been confusing to plumbing designers. Chapter 11 includes requirements for all other storage and handling of medical gas cylinders. 3 a cylinder and container management storage and reserve requirements.
C electrical connections and requirements. D motor requirements and controls. B gas central supply and bulk supply systems except as addressed in this chapter. Nfpa 99 1999 has very specific requirements for storage of nonflammable medical gases exceeding 3 000 cu.
Requirements for cylinder storage locations that have large volumes of stored gas. Compressed gas cylinders must be secured in racks or by chains. E systems having nonstandard operating pressures except as addressed in this chapter. No flammable liquids or gases may be stored within the room.
It is not uncommon to find motor driven equipment in the same room as medical gas storage in existing facilities but this is one example where the requirements for new facilities do not apply to existing facilities. Meaning you should review yours now if you haven t already. More recently many states have adopted and enforced the fgi guidelines. F waste anesthetic gas disposal wagd systems.
Flammable and combustible materials must be a minimum 5 feet from cylinder storage 20 feet if the room is not protected by automatic sprinklers. Typical medical gases whose storage can be comingled with oxygen include.