Minimum Stair Headroom Clearance
Clearances for stair construction inspection.
Minimum stair headroom clearance. Stairs required to be accessible by 4 1 shall comply with 4 9. The minimum headroom in all parts of the stairway shall not be less than 6 feet 8 inches 2036 mm measured vertically from the sloped plane adjoining the tread nosing photo 4 or from the floor surface of the landing or platform. Ada standards for projecting hazard clearances. This document provides building code specifications sketches photographs and examples of the stair passage width stair overhead clearance or head room needed for indoor or outdoor stairs.
1910 25 d 4 have a minimum tread depth of 7 5 inches 19 cm measured at a point 12 inches 30 cm from the narrower edge. Stairway headroom width codes requirements. Stairway headroom or overhead clearance. Headroom clearance of at least 80 high is required along all circulation paths except at doors and doorways where a 78 minimum clearance is permitted to accommodate door stops and closers.
Headroom clearance 1 except as provided by sentences 2 4 and 5 every exit shall have a clear height over the clear width of theexit of not less than 2 100 mm. R311 5 3 stair treads and risers. The maximum rise and minimum going on a private stair should not be used together as this will result in a pitch greater than the recommended maximum. 2 the clear height of stairways shall be measured vertically over the clear width of the stairway from a straight line tangent to the tread and landing nosings to the.
Handrail graspability to be either type i or ii with a minimum 1 1 2 inch clearance from a wall. What is the minimum headroom clearance for stairs. Maximum 12 3 vertical height rise for a flight of stairs. Minimum 6 8 headroom height clearance for stairway.
Clause 4 2 10 should be referred to for exceptions where a private stair should meet the above recommendations for any other stair. Minimum 10 inch stair tread depth with nosing or minimum 11 inches with no nosing. Such headroom shall be continuous above the stairway to the point. Stairs shall comply with 504.
Maximum 7 3 4 inch stair riser height. Headroom on stairs and ramps. Stairway height width headroom requirements. The distance from the top of the stair tread to the ceiling above measured at the stair tread nose should be six feet eight inches or more.
Thursday june 14 2018 headroom at stairs cannot be less than 6 feet 8 inches as measured vertically from the sloped line adjoining the tread nosing or platform on that portion of the stairway according to b oth the international residential code irc and the residential edition of. Stairways shall have a minimum headroom clearance of 80 inches 2032 mm measured vertically from a line connecting the edge of the nosings. The ontario building code headroom clearance 3 4 3 5.